• Atomic Absorption Spectrometer AA500 PG Instrument UK

    Atomic Absorption Spectrometer
    Model:AA500
    Brand:PG Instrument
    Origin: UK

    Flame Analysis Only (AA500F)
    Graphite Furnace Only (AA500G)
    Combined Flame and Furnace (AA500FG)

    The AA500 Atomic Absorption Spectrometer is a high performance automated instrument designed to meet the
    requirements of the modern laboratory. Due to its versatility and
    performance it can be used for a wide range of applications including:
    Agricultural, Clinical, Environmental, Food, Metal, Mining, Geological, Petrochemical, Pharmaceutical

    Technical Specifications
    Wavelength Range 185nm-910nm
    Monochromator Czerny-Turner Configuration (Double Beam Available)
    Spectral Bandwidth 0.1nm, 0.2nm, 0.4nm, 1.0nm, 2.0nm, (software selectable).
    Wavelength Accuracy ± 0.15nm
    Wavelength Reproducibility < 0.05nm
    Resolution 0.2nm ± 0.02nm
    Baseline Stability 0.005A/30min
    Sensitivity (Cu) 2 µg/ml Absorption > 0.28A (flame)
    Detection Limit Cu < 0.004 µg/ml (flame) Cd < 0.4 x 10-12g (graphite furnace)
    Repeatability Cu < 0.7% (Air/Acetylene flame),Ba < 1.0% (Nitrous oxide/Acetylene flame),Cu < 2.0% Cd < 2.0% (Graphite Furnace)
    Background Correction Deuterium Arc, Self reversal
    Characteristic Concentration Cu < 0.02 µg/ml, Ba < 0.15 mg/ml (N2O/Acetylene)
    Burner Heads Titanium Alloy(Burner position- Height and Rotation controlled via software)
    Nebuliser Micron Mist Inert Adjustable Nebuliser, Flow Rate from 2ml - 6ml/min. Pt/Ir capillary
    available for high acid concentration
    Position Adjustment Automatic changeover (AA500GF) Manual (AA500F)
    Automatic Setting of Optimum Height for Flame Burner
    Safety Functions Burner Identification, Flame Sensor, Gas leak Sensor, Low Gas
    Pressure Sensor, Drain Trap Sensor, Power Loss Protection,
    Circulation Water (graphite), Over Temperature Sensor (graphite)

    Flame Atomiser Features
    The flame atomiser offers three flame options:
    Air/acetylene is the standard configuration with the N2O/acetylene and Air/LPG as options.

    Air/Acetylene 
    The Air/Acetylene flame uses a 100mm single slot burner for the standard configuration.
    The high sensitivity (Cu 2ppm >0.280abs) is due to the efficiency of the fixed position glass nebuliser fitted as standard. An acid resistant replacement is available as an option.
    The flame can be easily set from blue lean flame through stoichiometric to fuel rich by means of computer control.

    N20/Acetylene
    The N2O/Acetylene flame uses a 50mm single slot burner and is available as an optional extra. (This burner is also known as the UNIVERSAL Burner.
    This flame configuration is used to measure elements less prone to ionization such as: Aluminium, Tin, Titanium, Calcium, Vanadium and Molybdenum.Switching from Air/Acetylene to N2O/Acetylene to Flame Off is fully controlled by the AAWinPro software.